Optimally stabilized PET image denoising using trilateral filtering

Awais Mansoor, Ulas Bagci, Daniel J. Mollura

Medical Image Computing and Computer-Assisted Intervention – MICCAI 2014: 17th International Conference, Boston, MA, USA, September 14–18, 2014, Proceedings, Part I. Lecture Notes in Computer Science, volume 8673, pages 130–137.

Abstract

Low-resolution and signal-dependent noise distribution in positron emission tomography (PET) images makes denoising process an inevitable step prior to qualitative and quantitative image analysis tasks. Conventional PET denoising methods either over-smooth small-sized structures due to resolution limitation or make incorrect assumptions about the noise characteristics. Therefore, clinically important quantitative information may be corrupted. To address these challenges, we introduced a novel approach to remove signal-dependent noise in the PET images where the noise distribution was considered as Poisson-Gaussian mixed. Meanwhile, the generalized Anscombe's transformation (GAT) was used to stabilize varying nature of the PET noise. Other than noise stabilization, it is also desirable for the noise removal filter to preserve the boundaries of the structures while smoothing the noisy regions. Indeed, it is important to avoid significant loss of quantitative information such as standard uptake value (SUV)-based metrics as well as metabolic lesion volume. To satisfy all these properties, we extended bilateral filtering method into trilateral filtering through multiscaling and optimal Gaussianization process. The proposed method was tested on more than 50 PET-CT images from various patients having different cancers and achieved the superior performance compared to the widely used denoising techniques in the literature.

Abstract source

This 2014 MICCAI conference paper presents a PET denoising method that combines noise stabilization with trilateral filtering. The authors evaluated it using phantom data and retrospectively collected PET-CT scans, comparing its performance with other denoising approaches.

Summary

The paper addresses signal-dependent noise in positron emission tomography (PET) images, where denoising can smooth small structures or alter quantitative measures. The proposed method models noise as a Poisson–Gaussian mixture, applies the generalized Anscombe transformation to stabilize noise variation, and then uses trilateral filtering to reduce noise while preserving boundaries. The evaluation included phantom data and retrospective PET-CT scans from 51 patients. The study reports comparisons with established denoising methods; it does not establish prospective clinical validation.

  • Authors: Awais Mansoor, Ulas Bagci, Daniel J. Mollura
  • Year: 2014
  • Venue: Medical Image Computing and Computer-Assisted Intervention – MICCAI 2014, 17th International Conference, Proceedings, Part I; Lecture Notes in Computer Science, volume 8673, pages 130–137
  • DOI: 10.1007/978-3-319-10404-1_17

Cite this work

Awais Mansoor, Ulas Bagci, Daniel J. Mollura (2014). Optimally stabilized PET image denoising using trilateral filtering. Medical Image Computing and Computer-Assisted Intervention – MICCAI 2014: 17th International Conference, Boston, MA, USA, September 14–18, 2014, Proceedings, Part I. Lecture Notes in Computer Science, volume 8673, pages 130–137. https://doi.org/10.1007/978-3-319-10404-1_17

BibTeX