Simultaneous detection and quantification of retinal fluid with deep learning

Dustin Morley, Hassan Foroosh, Saad Shaikh, Ulas Bagci

4th International Workshop on Ophthalmic Medical Image Analysis (OMIA 2017), held in conjunction with MICCAI 2017; RETOUCH challenge contribution (venue wording requires confirmation)

Abstract

We propose a new deep learning approach for automatic detection and segmentation of fluid within retinal OCT images. The proposed framework utilizes both ResNet and Encoder-Decoder neural network architectures. When training the network, we apply a novel data augmentation method called myopic warping together with standard rotation-based augmentation to increase the training set size to 45 times the original amount. Finally, the network output is post-processed with an energy minimization algorithm (graph cut) along with a few other knowledge guided morphological operations to finalize the segmentation process. Based on OCT imaging data and its ground truth from the RETOUCH challenge, the proposed system achieves dice indices of 0.522, 0.682, and 0.612, and average absolute volume differences of 0.285, 0.115, and 0.156 mm$^3$ for intaretinal fluid, subretinal fluid, and pigment epithelial detachment respectively.

Abstract source

This 2017 study describes a deep-learning approach to detect and segment retinal fluid in optical coherence tomography images, evaluated on RETOUCH challenge data. The authors also discuss limitations in the reference annotations used for evaluation.

Summary

Morley, Foroosh, Shaikh, and Bagci describe a convolutional neural network that processes individual optical coherence tomography (OCT) slices to identify intraretinal fluid, subretinal fluid, and pigment epithelial detachment. The approach combines a ResNet encoder–decoder architecture with data augmentation and graph-cut post-processing. The authors evaluated it using two-fold cross-validation on RETOUCH challenge data and reported Dice indices and absolute volume differences for the three fluid categories. They also noted concerns about the consistency of the reference annotations, particularly for intraretinal fluid, which may affect interpretation of the evaluation. See the paper on arXiv and the RETOUCH challenge paper PDF.

Cite this work

Dustin Morley, Hassan Foroosh, Saad Shaikh, Ulas Bagci (2017). Simultaneous detection and quantification of retinal fluid with deep learning. 4th International Workshop on Ophthalmic Medical Image Analysis (OMIA 2017), held in conjunction with MICCAI 2017; RETOUCH challenge contribution (venue wording requires confirmation) https://arxiv.org/abs/1708.05464