Single-channel sparse non-negative blind source separation method for automatic 3-d delineation of lung tumor in PET images

Ivica Kopriva; Wei Ju; Bin Zhang; Fei Shi; Dehui Xiang; Kai Yu; Ximing Wang; Ulas Bagci; Xinjian Chen

IEEE Journal of Biomedical and Health Informatics, 21(6), 1656–1666

Abstract

In this paper, we propose a novel method for single-channel blind separation of nonoverlapped sources and, to the best of our knowledge, apply it for the first time to automatic segmentation of lung tumors in positron emission tomography (PET) images. Our approach first converts a 3-D PET image into a pseudo-multichannel image. Afterward, regularization free sparseness constrained non-negative matrix factorization is used to separate tumor from other tissues. By using complexity based criterion, we select tumor component as the one with minimal complexity. We have compared the proposed method with threshold based on 40% and 50% maximum standardized uptake value (SUV), graph cuts (GC), random walks (RW), and affinity propagation (AP) algorithms on 18 nonsmall cell lung cancer datasets with respect to ground truth (GT) provided by two radiologists. Dice similarity coefficient averaged with respect to two GTs is: 0.78 ± 0.12 by the proposed algorithm, 0.78 ± 0.1 by GC, 0.77 ± 0.13 by AP, 0.77 ± 0.07 by RW, and 0.75 ± 0.13 by 50% maximum SUV threshold. Since the proposed method achieved performance comparable with interactive methods, considering the unique challenges of lung tumor segmentation from PET images, our findings support possibility of using our fully automated method in routine clinics. The source codes will be available at www.mipav.net/English/research/research.html.

Abstract source

This 2017 journal article describes an automated method for delineating lung tumors in 3-D PET images and compares it with threshold-based and interactive segmentation methods using 18 datasets.

Summary

The authors converted each 3-D positron emission tomography (PET) image into a pseudo-multichannel image, then applied sparseness-constrained non-negative matrix factorization to separate tumor from other tissues. A complexity-based criterion selected the tumor component. They evaluated the method on 18 non-small cell lung cancer datasets against reference segmentations provided by two radiologists, comparing it with thresholding, graph cuts, random walks and affinity propagation. This retrospective comparison does not establish prospective clinical validation. Read the article record and abstract.

Cite this work

Ivica Kopriva; Wei Ju; Bin Zhang; Fei Shi; Dehui Xiang; Kai Yu; Ximing Wang; Ulas Bagci; Xinjian Chen (2017). Single-channel sparse non-negative blind source separation method for automatic 3-d delineation of lung tumor in PET images. IEEE Journal of Biomedical and Health Informatics, 21(6), 1656–1666 https://doi.org/10.1109/JBHI.2016.2624798

BibTeX