The influence of intensity standardization on medical image registration

Ulas Bagci; Jayaram K. Udupa; Li Bai

Medical Imaging 2010: Visualization, Image-Guided Procedures, and Modeling, Proceedings of SPIE, vol. 7625, article 76251X

Abstract

Acquisition-to-acquisition signal intensity variations (non-standardness) are inherent in MR images. Standardization is a post processing method for correcting inter-subject intensity variations through transforming all images from the given image gray scale into a standard gray scale wherein similar intensities achieve similar tissue meanings. The lack of a standard image intensity scale in MRI leads to many difficulties in tissue characterizability, image display, and analysis, including image segmentation. This phenomenon has been documented well; however, effects of standardization on medical image registration have not been studied yet. In this paper, we investigate the influence of intensity standardization in registration tasks with systematic and analytic evaluations involving clinical MR images. We conducted nearly 20,000 clinical MR image registration experiments and evaluated the quality of registrations both quantitatively and qualitatively. The evaluations show that intensity variations between images degrades the accuracy of registration performance. The results imply that the accuracy of image registration not only depends on spatial and geometric similarity but also on the similarity of the intensity values for the same tissues in different images.

Abstract source

This 2010 SPIE Medical Imaging paper examines how intensity variation affects the registration of brain MR images. Its controlled experiments compare registration performance across standardized and artificially varied image intensities.

Summary

The paper studies whether intensity standardization affects medical image registration—the process of spatially aligning images. The authors evaluated brain MR images using controlled intensity variations and known affine deformations. They report that intensity variation generally reduced registration performance in their experiments, while noting that the evaluation focused on specific MRI protocols and an intra-modality registration setting.

Cite this work

Ulas Bagci; Jayaram K. Udupa; Li Bai (2010). The influence of intensity standardization on medical image registration. Medical Imaging 2010: Visualization, Image-Guided Procedures, and Modeling, Proceedings of SPIE, vol. 7625, article 76251X https://doi.org/10.1117/12.843969

BibTeX